Caution / Warning
1.
Always follow instructions, including
wearing the respirator with filter cartridge properly and continuously during
exposure. Incorrect use may lead to excessive exposure to contaminants,
resulting in illness or death.
2.
Before each use, carefully inspect the whole
respirator set to ensure it is in good condition. Replace any damaged or
defective components before use.
3.
Fully
charge the purifier cartridge before first use.
4.
Do not use if facial hair, hair, or
other conditions prevent direct sealing between the face and the edges of the
respirator.
5.
Do not use solvents to clean the
respirator, as this may cause certain components to deteriorate and reduce the
respirator's effectiveness.
6.
(If
applicable) Prior to use, employers must provide users with training on proper
respirator usage in accordance with safety and health regulations.
7.
If
you detect odors tastes of contaminants, feel dizzy, experience irritation, or
any other discomfort while using the respirator, immediately leave the
contaminated area.
8.
This
respirator must not be used when contaminant concentration is unknown, reaches
IDLH (Immediately Dangerous to Life or Health) levels, or exceeds limits set by
local regulations.
9.
This
respirator does not supply oxygen. Do not use it in environments where oxygen
levels are below 19.5%.
10.
Modification,
misuse, incorrect use, or alteration of the respirator facepiece, filters, or
cartridges is prohibited.
11.
Improper
disposal of used filters, cartridges, or facepieces containing harmful
substances can harm the environment. Used components must be handled,
transported, and disposed of in accordance with local laws and regulations.
12.
In
high humidity and dusty environments, poor ventilation may reduce performance.
Keep the device clean for optimal use.
13.
The
purifier cartridge is not waterproof. Avoid using or storing it in extreme
temperatures or high humidity, or exposing it to rain, to prevent damage or affect
performance and lifespan.
14.
If
you detect any unusual noises, chemical or burning smells, or smoke coming from
the purifier cartridge, immediately stop using the product and contact the
manufacturer.
Battery (cautions and recycling)
1. The purifier
cartridge contains a non-removable
battery. Never attempt to disassemble, puncture, or modify the battery.
2.
Do not expose the battery to excessive heat,
moisture, or direct sunlight. Keep away from sharp objects to prevent
short-circuiting.
3.
Charge the battery by using 5V/1A cord and within
the temperature range of 50°F to 104°F. Charging outside this range may shorten
battery life, extend charging time, or stop charging for safety reasons.
4.
Do not overcharge or over discharge
the battery. If unused for long periods, charge and discharge it every three
months to maintain battery health.
5.
If the battery is obviously swollen or abnormally
hot, stop using it. If the above-mentioned abnormal condition continues, please
contact the manufacturer.
6.
Please dispose of this product and its battery in
accordance with local laws and regulations. Do not dispose of the battery in
regular household waste.
7.
For battery disposal, please contact your local
recycling center or authorized disposal facility. Recycling helps to conserve
natural resources and prevents harmful chemicals from contaminating the
environment.
Respirator
inspection
1. Check
for cracks, damage, or dirt on the respirator. Ensure that the respirator,
especially the areas in contact with the face, is not deformed. The material
should be soft, not stiff.
2. Inspect
the inhale valve for any signs of warping, cracking, or damage. Lift the valve
flap and check the valve seat for dirt or cracks. Similarly, check the exhale
valve and replace them if necessary.
3. Ensure
the head strap is intact and has good elasticity. Replace it if needed.
4. Check
that the gasket is properly installed and free from damage or dirt. Replace it
if necessary.
5. Inspect
the purifier cartridge, filter cover and filters for any damage, cracks, or
dirt.
Structure
1. Charging cable 7-2. Control button
2. Filter cover 7-3. Cover buckle
3. Activated carbon 7-4. Charging port (Type-C)
4. H13 HEPA 8. Respirator
5. Micro fan 8-1. Head harness
6. Li-Po battery 8-2. Inhale valve
7. Purifier cartridge 8-3. Exhale valve
7-1. ED Indicator & illumination 8-4. Gasket
Installation
1.
Hold both sides of purifier cartridge
and gently open cover buckle to remove filter cover.
2.
H13
HEPA:Take HEPA filter out from packing bag and place into
rectangle slot on purifier cartridge, surrounding by O-ring, with filter’s tab facing
out.
3.
Activated
carbon:Take out activated carbon from packing bag, and place
it into the inner side of filter cover.
4.
Align
hole on top edge of filter cover with lugs on purifier cartridge and press
bottom buckle until hear a "click" sound to secure it.
* Suggested to replace H13 HEPA
every 2 weeks, or earlier if breathing resistance is felt.
* When
replacing filter, do not touch fan in round hole to prevent damage.
1. Hold respirator and purifier cartridge with both hands, align
"JK2L" (on top cover) with "Unlock" (above intake port),
and press firmly.
2. Rotate the purifier cartridge clockwise as indicated by arrow until
"JK2L" reaches the "Lock".
3. To uninstall the purifier cartridge, rotate it counterclockwise until
"JK2L" aligns with the "Unlock", then remove the purifier
cartridge.
*When installing purifier cartridge, follow the
indicated directions to ensure proper fit.
1. Place
head cradle at back of head. Pull strap downward and backward to ensure
respirator fully covers your mouth and nose.
2. Pull
lower strap to back of neck, secure it with buckle, and adjust tension for
optimal seal and visibility. Repeat if necessary.
3. Tighten
lower strap to adjust upper tension, ensuring both side straps are evenly
tightened. Adjust respirator position for comfort.
Charging
1. Open
power port cover and plug charging cord into power port.
2.
Breathing light will flash during
charging, and will be displayed according to current charging status, from low
to high:
Red(1 LED)>Yellow(2 LED)>Blue(3 LED)>Green(4
LED)
* When fully charged, it will remain green LED and
sound a beep.
*
Avoid forcefully plugging or unplugging power port cover and cable to prevent
damage.
Operating
Adjust
wind speed
Turbo wind: blue light, one short beep.
Strong wind: yellow light, two short
beeps.
Off: White light flashes twice, one
long beep.
* Each press control button to switch mode
cyclically.
* Flowing light shows mode every 5 minutes.
*
When battery is low, it alerts with 3 short beeps and flashes red light 3 times
every 2 minutes as a reminder.
Lighting
Mode
ON/
OFF: Press and hold control button 3 seconds.
Cleaning & Storage
1. Remove purifier cartridge. If necessary, inhale valve, exhale valve, gasket, and head harness can also be removed. Do not attempt to remove any other parts of respirator.
2. Soak respirator in neutral detergent solution and clean it with soft brush. Do not use oil-based cleaners.
l Do not exceed water temperature of 140°F. Do not machine wash or use solvent-based cleaners.
3. Rinse respirator with clean water and allow it to air dry in cool, dry place away from contaminants.
lThis step is for cleaning respirator body only. Purifier cartridge and filters should not be washed, as doing so may damage them and affect performance.
4. Store respirator in environment away from particles, chemicals, and direct sunlight, with storage temperature range of (-4°C~104°C) and humidity <80%. Avoid damage and deformation. Respirator is valid for 5 years.